available-technology

Triple Port / Single Port Pressure Sensor

available-technology

Triple Port / Single Port Pressure Sensor

Application field : Cardiac SurgeryCardiopulmonary supportECMO
Measured Parameters : Blood temperature (Tblood)

Unique Features

1.

Reusable pressure monitoring: stop throwing away electronics.

2.

Calibration free: sensor is fully calibrated in house before shipment.

3.

Non-invasive continuous monitoring of blood pressure in blood.

4.

No calculation is required at the host equipment level, pressure values with different measurement units can simply be displayed

1.

Reusable pressure monitoring: stop throwing away electronics.

2.

Calibration free: sensor is fully calibrated in house before shipment.

3.

Non-invasive continuous monitoring of blood pressure in blood.

4.

No calculation is required at the host equipment level, pressure values with different measurement units can simply be displayed

Description

The pressure sensor represents the evolution in monitoring the blood pressure in the custom packs used for extra-corporeal therapies such as ECMO, Organ preservation, ECLS in general. The sensor is reusable and can be easily connected to any Luer-lock port by interposing a transducer protector.

 

Range, Accuracy & Resolution
ParameterMeasured Ranges/Accuracy
Pressure range-50 – +900 mmHg
Blood temperature range20.0 – 40.0 °C
Pressure accuracy±1.50% Total Error Band after zero adjust
Response TimeResponse time for a 0 to 300 mmHg pressure step change is: 5 ms
Technical Details
ParameterDescription
Power supply+5V ±5% @100mA
+12V ±5% @80mA
Communication interfaceI2C
Shelf-life3 years

Why are still discarding eletronics after every ECMO or CPB procedures?

In most ECMO and CPB systems, pressure monitoring relies on disposable electronic transducers. After each treatment you have: electronic waste, recurrent cost and no technological advantage. It’s time to rethink this architecture, introducing a reusable pressure monitoring platform.

 

Rethink the architecture

Single-Use Transducer Protector

The innovation is simple and strategic: the sensing electronics are completely isolated from the fluid path through a standard commercial transducer protector.
No direct blood contact. No contamination risk. No disposable electronics.

Designed for: ECMO systems, CPB platforms, Extracorporeal blood circuits, Medical and Pharma fluid monitoring

Two configurations

Available in two configurations:

  • One Channel Version – compact, streamlined integration
  • Three Channels Version – multi-point pressure monitoring